Fitting fire-rated roller shutters in Abergavenny
If your address has an NP7 postcode, it falls within our Gwent coverage. Ebbw Vale, Pontypool and Cwmbran are covered too, which helps when several properties need doing.
Abergavenny is roughly 18 miles north of Newport.
Conveyor openings, kitchen hatches and doors between warehouse compartments are typical places a fire shutter is needed in commercial buildings in Abergavenny.
Where a fire shutter is part of new building work in Abergavenny, the approval route and the product evidence are confirmed before anything is ordered.
Specifying fire-rated roller shutters for Abergavenny
What you can choose when we survey in Abergavenny:
- RatingIntegrity ratings typically from 60 up to 240 minutes, depending on the tested product; smoke-rated versions only where tested to BS EN 1634-3.
- ReleaseFusible link, local heat detector or fire alarm interface, as the fire strategy specifies, with fail-safe closing.
- TypeFull-height shutters, or fire-rated counter shutters for hatches.
Prices for fire-rated roller shutters in Abergavenny
| Fire-rated roller shutters | Ex VAT | Inc VAT |
|---|---|---|
| Fire shutter around 3,000 × 3,000 mm | £3,495 – £7,995 | £4,195 – £9,595 |
| Fire-rated counter shutter | £1,495 – £2,995 | £1,795 – £3,595 |
| Fire shutter service including drop test, per shutter | £125 – £245 | £150 – £295 |
Guide prices, supplied and fitted unless stated. VAT at 20% where it applies.
Prices are typical for the UK and apply in Abergavenny too; the survey confirms the size and specification before you get a fixed price.
Planning and safety in Abergavenny
As a Welsh town, Abergavenny follows the Town and Country Planning Act 1990 and the Welsh permitted development rules.
- Alarm link: Linking a shutter to the fire alarm is coordinated with your alarm contractor so the shutter closes on the right signal; shutters across escape routes are normally released by local heat detection.
- Certification: We supply the manufacturer's test or certification evidence for the product we quote. We do not claim a rating on our own behalf.
- Approvals: Where a fire shutter forms part of building work, such as a new or altered opening in a compartment wall, building regulations approval is needed from local authority building control.
- Your duties: In England and Wales, the responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire safety equipment, including fire shutters, maintained in good working order.
How it works in Abergavenny
Start with a guide price
Our quote tool gives a guide range in a couple of minutes, or just send us the details.
Survey at the property
A surveyor measures, checks what the box and guides will fix to, and talks through options.
One clear quotation
Everything included is listed, and nothing is ordered until you accept.
Made, fitted, handed over
Your shutter is made to measure, fitted, set up and demonstrated.
Frequently asked questions
Who is responsible for maintaining fire shutters?
The person responsible for fire safety in the building: the responsible person in England and Wales, the duty holder in Scotland or the appropriate person in Northern Ireland.
What does a fire rating mean?
It is the time the tested shutter held back fire in a standard furnace test. The rating applies to the tested product installed as its manufacturer specifies.
Is the survey free in Abergavenny?
Yes, for new installations. We tell you the cost of any repair or service visit before booking.
Do you cover Abergavenny?
Yes. Book a survey for any address in Abergavenny in the usual way; it is covered as part of Gwent.