Fire shutters for properties in Hawick
Hawick is roughly 20 miles south of Galashiels.
Fire shutters for buildings in Hawick are specified from the fire strategy: the rating, the release method and how the shutter links to the alarm.
Conveyor openings, kitchen hatches and doors between warehouse compartments are typical places a fire shutter is needed in commercial buildings in Hawick.
Hawick is part of our Scottish Borders coverage, and addresses in the TD9 postcode district are covered in the same way as the rest of Scottish Borders. Our coverage around Hawick also includes Kelso, Galashiels and Peebles.
Specifying fire-rated roller shutters for Hawick
What you can choose when we survey in Hawick:
- TypeFull-height shutters, or fire-rated counter shutters for hatches.
- ReleaseFusible link, local heat detector or fire alarm interface, as the fire strategy specifies, with fail-safe closing.
- RatingIntegrity ratings typically from 60 up to 240 minutes, depending on the tested product; smoke-rated versions only where tested to BS EN 1634-3.
Guide prices for Hawick
| Fire-rated roller shutters | Ex VAT | Inc VAT |
|---|---|---|
| Fire shutter around 3,000 × 3,000 mm | £3,495 – £7,995 | £4,195 – £9,595 |
| Fire-rated counter shutter | £1,495 – £2,995 | £1,795 – £3,595 |
| Fire shutter service including drop test, per shutter | £125 – £245 | £150 – £295 |
Guide prices, supplied and fitted unless stated. VAT at 20% where it applies.
Guide prices only: access, fixings, power and finish at your property in Hawick can move the figure up or down, and the survey settles it.
What to check in Hawick before ordering
Hawick is in Scotland, so planning decisions sit with your planning authority (the local council, or a national park authority).
- Alarm link: Linking a shutter to the fire alarm is coordinated with your alarm contractor so the shutter closes on the right signal; shutters across escape routes are normally released by local heat detection.
- Your duties: In Scotland, the duty holder under the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 must keep fire safety measures maintained.
- Approvals: Where a fire shutter forms part of building work, such as a new or altered opening in a compartment wall, a building warrant from the council's building standards service is normally needed before work starts.
- Certification: We supply the manufacturer's test or certification evidence for the product we quote. We do not claim a rating on our own behalf.
What happens next
Tell us about the opening
Use the quote tool or the form: the type of shutter, rough sizes and any photos.
Measured on site
Exact sizes, box space, power and controls are confirmed on site.
One clear quotation
Everything included is listed, and nothing is ordered until you accept.
Fitted and explained
Installed, set up and shown to you, with the manufacturer's paperwork.
Frequently asked questions
Who is responsible for maintaining fire shutters?
The person responsible for fire safety in the building: the responsible person in England and Wales, the duty holder in Scotland or the appropriate person in Northern Ireland.
What does a fire rating mean?
It is the time the tested shutter held back fire in a standard furnace test. The rating applies to the tested product installed as its manufacturer specifies.
Is the survey free in Hawick?
Yes, surveys for new installations in Hawick are free. Repair and service visits are charged.
How much do fire-rated roller shutters cost in Hawick?
The guide prices above apply in Hawick. Your exact price depends on size, finish, controls and access, and is fixed in writing after survey.