Fitting fire-rated roller shutters in Leatherhead
Leatherhead is part of our Surrey coverage, and addresses in the KT22 postcode district are covered in the same way as the rest of Surrey. Other towns nearby that we cover include Epsom, Ewell and Esher.
Leatherhead is roughly 11 miles east of Guildford.
Fire shutters for buildings in Leatherhead are specified from the fire strategy: the rating, the release method and how the shutter links to the alarm.
We work with your fire alarm contractor in Leatherhead so the shutter closes on the right signal and the interface is tested at handover.
Specifying fire-rated roller shutters for Leatherhead
What you can choose when we survey in Leatherhead:
- TypeFull-height shutters, or fire-rated counter shutters for hatches.
- RatingIntegrity ratings typically from 60 up to 240 minutes, depending on the tested product; smoke-rated versions only where tested to BS EN 1634-3.
- ReleaseFusible link, local heat detector or fire alarm interface, as the fire strategy specifies, with fail-safe closing.
Prices for fire-rated roller shutters in Leatherhead
| Fire-rated roller shutters | Ex VAT | Inc VAT |
|---|---|---|
| Fire shutter around 3,000 × 3,000 mm | £3,495 – £7,995 | £4,195 – £9,595 |
| Fire-rated counter shutter | £1,495 – £2,995 | £1,795 – £3,595 |
| Fire shutter service including drop test, per shutter | £125 – £245 | £150 – £295 |
Guide prices, supplied and fitted unless stated. VAT at 20% where it applies.
Prices are typical for the UK and apply in Leatherhead too; the survey confirms the size and specification before you get a fixed price.
Rules that apply in Leatherhead
Leatherhead is in England, so planning decisions sit with your local planning authority (the district, borough, city or unitary council).
- Approvals: Where a fire shutter forms part of building work, such as a new or altered opening in a compartment wall, building control approval is needed, from the council or a registered building control approver.
- Your duties: In England and Wales, the responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire safety equipment, including fire shutters, maintained in good working order.
- Certification: We supply the manufacturer's test or certification evidence for the product we quote. We do not claim a rating on our own behalf.
- Alarm link: Linking a shutter to the fire alarm is coordinated with your alarm contractor so the shutter closes on the right signal; shutters across escape routes are normally released by local heat detection.
From survey to fitting
Send the basics
Tell us what the shutter is for and the rough size, with photos if you have them.
Measured on site
Exact sizes, box space, power and controls are confirmed on site.
Fixed written price
You get a quotation listing the shutter, controls, fitting and lead time.
Fitted and explained
Installed, set up and shown to you, with the manufacturer's paperwork.
Fire-rated roller shutters in Leatherhead: questions
What does a fire rating mean?
It is the time the tested shutter held back fire in a standard furnace test. The rating applies to the tested product installed as its manufacturer specifies.
Who is responsible for maintaining fire shutters?
The person responsible for fire safety in the building: the responsible person in England and Wales, the duty holder in Scotland or the appropriate person in Northern Ireland.
Do you cover Leatherhead?
Yes. Book a survey for any address in Leatherhead in the usual way; it is covered as part of Surrey.
Do I need permission for fire-rated roller shutters in Leatherhead?
A fire shutter must suit the building's fire strategy, and fire shutters forming part of building work need building control approval (a building warrant in Scotland). If you are unsure, ask your local council; we provide product details for any application.