Fire-rated roller shutters in Gateshead
For reference, Gateshead lies about 1 mile south-east of Newcastle upon Tyne.
Where a fire shutter is part of new building work in Gateshead, the approval route and the product evidence are confirmed before anything is ordered.
Conveyor openings, kitchen hatches and doors between warehouse compartments are typical places a fire shutter is needed in commercial buildings in Gateshead.
Gateshead is part of our Tyne and Wear coverage, and addresses in the NE8 postcode district are covered in the same way as the rest of Tyne and Wear. Our coverage around Gateshead also includes Newcastle upon Tyne, Wallsend and Hebburn.
Specifying fire-rated roller shutters for Gateshead
What you can choose when we survey in Gateshead:
- RatingIntegrity ratings typically from 60 up to 240 minutes, depending on the tested product; smoke-rated versions only where tested to BS EN 1634-3.
- TypeFull-height shutters, or fire-rated counter shutters for hatches.
- ReleaseFusible link, local heat detector or fire alarm interface, as the fire strategy specifies, with fail-safe closing.
Guide prices for Gateshead
| Fire-rated roller shutters | Ex VAT | Inc VAT |
|---|---|---|
| Fire shutter around 3,000 × 3,000 mm | £3,495 – £7,995 | £4,195 – £9,595 |
| Fire-rated counter shutter | £1,495 – £2,995 | £1,795 – £3,595 |
| Fire shutter service including drop test, per shutter | £125 – £245 | £150 – £295 |
Guide prices, supplied and fitted unless stated. VAT at 20% where it applies.
Use these as a starting point for budgeting in Gateshead; the written quotation after survey is the price that counts.
Rules that apply in Gateshead
As an English town, Gateshead follows the Town and Country Planning Act 1990 and the permitted development rules in England.
- Alarm link: Linking a shutter to the fire alarm is coordinated with your alarm contractor so the shutter closes on the right signal; shutters across escape routes are normally released by local heat detection.
- Approvals: Where a fire shutter forms part of building work, such as a new or altered opening in a compartment wall, building control approval is needed, from the council or a registered building control approver.
- Your duties: In England and Wales, the responsible person under the Regulatory Reform (Fire Safety) Order 2005 must keep fire safety equipment, including fire shutters, maintained in good working order.
- Certification: We supply the manufacturer's test or certification evidence for the product we quote. We do not claim a rating on our own behalf.
How it works in Gateshead
Send the basics
Tell us what the shutter is for and the rough size, with photos if you have them.
Free survey
We measure the opening and the space around it, and check fixings and power.
One clear quotation
Everything included is listed, and nothing is ordered until you accept.
Installation and handover
We fit, test the controls and safety devices, and leave the documents with you.
Fire-rated roller shutters in Gateshead: questions
What does a fire rating mean?
It is the time the tested shutter held back fire in a standard furnace test. The rating applies to the tested product installed as its manufacturer specifies.
How often should a fire shutter be tested?
Manufacturers and guidance such as BS 9999 recommend servicing at least once a year, including a drop test. Busy sites or insurers may ask for more often.
Is the survey free in Gateshead?
Yes, for new installations. We tell you the cost of any repair or service visit before booking.
Do you cover Gateshead?
Yes, we survey and fit in Gateshead (NE8) as part of our Tyne and Wear coverage.